Pro Steel Solutions Ltd Steel detailing

Steel tools

Section weight and paint area

Typical UK sections. Mass per metre and painted area are rounded; check critical values against the Blue Book.

Plate, flat and round bar weight

Steel at 7850 kg per cubic metre.

Tonnage from floor area

Early-stage estimate when you have a floor plan but no member schedule.

Paint quantity

Litres from area, dry film thickness, volume solids and losses.

Bolt length, hole size and spacing

Normal clearance holes and EN 1993-1-8 minimum spacing. Grip is the total thickness of the plies.

Fillet weld size and weight

Throat is 0.7 times leg length. Weight includes 10% for reinforcement.

Stair geometry check

Approved Document K limits for rise, going, pitch and 2R + G.

Guarding height

Minimum barrier heights from Approved Document K. Openings must stop a 100 mm sphere where children may be present.

Rafter length and rise

For a symmetrical duo-pitch portal frame.

Running dimension generator

Type the gaps between witness lines. You get the running values that sit at each point, ending at the overall length.

Unit converter

Common steelwork conversions.

Concrete pad bearing pressure

Check a base plate / pad size against the ground bearing pressure. Uses factored axial load only; moments should be checked separately.

Steel grade and yield stress

Characteristic yield stress f<sub>y</sub> and ultimate strength f<sub>u</sub> for common structural grades to BS EN 10025.

Notched beam (coped end)

Simplified shear capacity check for a notched beam web to BS EN 1993-1-1 §6.2.6. Check also block shear and local buckling for deep notches.

Weld classification (fatigue)

Detail category to BS EN 1993-1-9 for common weld types. Gives the characteristic fatigue strength Δσ<sub>C</sub> at 2×10⁶ cycles.

Fire resistance indication

Indicative fire rating for unprotected steelwork by section factor A<sub>m</sub>/V. Add intumescent or board to reach R60 or R90. Always confirm with a fire engineer.